How UKAS accreditation works for testing laboratories
The United Kingdom Accreditation Service is the national accreditation body recognised by the UK government. A testing laboratory accredited by UKAS has been assessed against ISO/IEC 17025:2017, the international standard for the competence of testing and calibration laboratories. Unlike ISO 9001 certification, which looks at a management system, this assessment covers technical competence for specific tests.
UKAS material describes well over 1,000 accredited testing laboratories. We could not open the UKAS directory to count them, so the figure of about 1,000 on this page is a rough estimate, and it moves as laboratories join and leave.
The certificate is not the scope
Each laboratory has a certificate carrying a number, and a separate schedule of accreditation carrying the same number. The certificate confirms that accreditation exists. The schedule states which materials, tests, methods and ranges are covered, and it can be revised and reissued. The most important check for a buyer is therefore not whether a laboratory is accredited, but whether the exact test on the purchase order appears on its schedule.
Testing and calibration are numbered separately, too. Lucideon, for example, states a testing number of 0013 and a calibration number of 0420. A number on a calibration certificate says nothing about testing competence.
Choosing a laboratory
| Sector | What to check on the schedule |
|---|---|
| Construction and fire | The named test standard, and whether site testing is included as well as laboratory work |
| Food and veterinary | Matrix, analyte and limit of detection |
| Environmental | Sample type, and whether sampling itself is accredited |
| Textiles and consumer goods | Whether a flexible scope covers the method revision you need |
Practical points for procurement
- Ask for the current schedule rather than a stored certificate, since the schedule is the live description of scope.
- Check that the report will carry the UKAS symbol. Laboratories can do unaccredited work as well, and such results are normally marked as outside the scope.
- Confirm the site. Accreditation attaches to named locations, so a group with several laboratories may not hold the same scope at each.
- For export work, ask about international recognition. UKAS is a signatory of the ILAC mutual recognition arrangement, which supports acceptance of reports abroad.